VIEW ISO 9000 CERTIFICATE

concrete tester concrete tester

Portable Ultrasonic Concrete Tester


4600 is fully portable instrument for assessing the strength of concrete either in situ or precast. It complies with the British Standard BS-4408 (Part V - 1974) and ASTM C-597.

4600 is designed with field conditions in mind and is very simple to operate. Its accuracy and stability is unmatched. 4600 generates low frequency pulses and measures the time of flight in the material. The time is displayed by 5 digit display. The time of flight and hence the velocity is related to the mechanical strength of concrete. The majority of concrete testing requires transducers with frequency of 50 to 100kHz. However higher frequencies are preferred for testing small specimens and achieving better timing accuracies. Wide range of transducers are offered with 4600. The high quality of transducers has been exploited to the fullest extent and the accuracy of the measurement is improved over the entire range to 100 nano seconds.

4600 M is a Microprocess version with following special features.

  1. Direct measurement of strength in Kg/cm².
  2. Minimum time and maximum velocity measurement.
  3. Storage of data.
  4. PC Interface for further statistical analyasis.


Battery Low Indication


Continuous analog indication of Battery condition is displayed by LED.


Standard Accessories


  1. 1 set of 7.2 volt NICAD Cells.
  2. Charger
  3. Probe Cables: 2 Nos. (4 Mts. each).
  4. Transducers: PC200 - 0.1 (2 Nos).(2" diameter, 100 kHz).
  5. Calibration Block


Optional Accessories


2" dia transducers
PC 200-0.025 - 25 kHz transducer.
PC 200-0.05 - 50 kHz transducer.
PC 200-0.2 - 200 kHz transducer.

1" dia transducers
PC 100-0.025 -25 kHz transducer.
PC 100-0.05 - 50 kHz transducer.
PC 100-0.2 - 200 kHz transducer.
(Standard UHF Connector).

Specifications
Test Mode : Through Transmission mode.
Range : 0.1 µ sec. to 9999.9 µ sec (upto 5 mts in concrete)
Measurement Units : Time (in µ sec).
Resolution : 0.1 µ sec.
Calibrated Accuracy : 0.1 µ sec.
Display : 5 digit / (2 x 16 Lcd Display) for model 4600 M.
Transducer : Contact Type
Operating Temperature : 0° to 50°C.
Power : 7.2 V.D.C
Display Response Time : Instantaneous.
Zero adjust : Through Multiturn Potentiometer.
Battery Low Indication : Continuous Analog Meter.
Dimensions : 250 x 65 x 260 mm.
Weight : 2.8 Kgs. approx.

NDT || Accessories || Custom built systems || Thickness guage
Hardness Tester || Transducer